WebA gas piping system that contains any corrugated stainless steel tubing (CSST) shall be electrically continuous and shall be directly bonded to the electrical service grounding electrode system. No portion of the gas piping system shall be used as or considered to be a grounding electrode or a grounding electrode conductor. CSST shall be installed and … WebNov 9, 2013 · The equipment grounding conductor for the circuit that is likely to energize the piping shall be permitted to serve as the bonding means. The points of attachment of the bonding jumper(s) shall be accessible. The CSST gas lines do not appear to be properly bonded as required by IRC G2411.1.1 (310.1.1) CSST.
Bonding your CSST gas lines: Minnesota updates its rules - Star Tribune
WebJun 5, 2013 · Eliminate the potential for stray voltage to damage CSST by properly bonding it to the home’s grounding system, no matter if you installed the piping or not. Give the … WebRecall that the CSST piping will already be bonded to some degree by the appliance grounding conductor(s)…assuming that it s connected to appliances that are electrically powered. This bonding however, is not considered to be adequate to protect CSST, therefore Section 310.1.1 mandates a more effective bonding means. Directly bonding … shanta velaiutham
wiring - Running ground wire from CSST to house ground
WebAug 20, 2012 · Gas lines are bonded and only require extra bonding if its CSST and this bond line must be 6 AWG copper to the electric grounding conductor from the point of entry for the gas not a rod to ground. All … WebApart from being ground-resistant, the newer black-coated pipes pull easier and lay straighter too. Obviously, these make black-coated CSST pipes the top choice. That being said, the grounding system requirements in … WebApart from being ground-resistant, the newer black-coated pipes pull easier and lay straighter too. Obviously, these make black-coated CSST pipes the top choice. That … poncho romancho bengali comics